INSTALLATION

WIRING DIAGRAMS

CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
tion.

If any of the original wires as supplied with the
appliance must be replaced, it must be replaced
with CSA type SEW (200

o

C) or its equivalent.

This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However, a
120V A.C. power supply is needed for the fan/
blower operation.

Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the cor-

rect fi ring rate (rate noted on label) at 15
minutes.

2) If required, adjusting the primary air to

ensure that the fl ame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility
of the manufacturer.