Operating Manual Light Control „PULSE HFMD - Vers. IV“

ENG

Changing basic settings - Part 1

Change to
parameterisation mode

Keep both switches [I and II]

pressed simultaneously for 10

seconds.

- The operating panel changes to

the parameterisation mode (first

to setting level 1).

- The background lit logo flashes

(once per second). The LEDs valid

for the level are lit on the light

bar:

LED 1

Level 1

LED 1+2

Level 2

LED 1+2+3

Level 3

LED 1+2+3+4

Level 4

Fig. 3

Key I

Logo

Light

bar
Key II

LED I

LED II

Change setting level

If both keys [I and II] are pressed

repeatedly within 5 seconds, the

next level is called.

- Level 2 is reached when the logo

stops flashing. LEDs 1+2 are lit

on the light bar.

- Level 3 is reached when the logo

starts flashing again. LEDs 1+2+3

are lit on the light bar.

- Level 4 is reached when the

logo stops flashing again. LEDs

1+2+3+4 are lit on the light bar.

Change function

When the desired setting level is

reached, the setting of the first

function (x.1) is displayed on the

light bar (LED 1 is lit or LED flashing

dark green).

By pressing key II, it is now possi-

ble to switch between functions.

- The LED valid for the level is lit or

flashes on the light bar:

LED 1

Function x.1

LED 2

Function x.2

LED 3

Function x.3

LED 4

Function x.4

LED 5

Function x.5

LED 6

Function x.6

LED 5+6

Function x.7

LED 1 2 3 4 5 6

Fig. 6