Installation and Operation

SECTION 5

5.5 Installation of TempZone™ Floor Heating Cable (Twin)

5.5.1 Install TempZone™ Cable Fixing Strips

Install Cable Fixing Strips in a direction perpendicular to the direction the cable will run. Cable Fixing Strips should be

installed at least 3 inches from the wall perimeter. WarmlyYours recommends securing the cable to the floor every 20

inches using tape or hot glue to keep the cable in position until the self-leveling underlayment is applied. When working

around cabinets or vanities, install the Cable Fixing Strips at a distance that will allow the cable to be installed 1-1/2 inches

away from the cabinet or vanity base.

Each row of Cable Fixing Strips should be positioned at the appropriate intervals to ensure the desired OC spacing (3 or 4

inches) for the installation.

Secure the Cable Fixing Strips to the floor. There are several acceptable methods for doing so.

For plywood, cement board, or similar surfaces:

• Secure Cable Fixing Strip with galvanized nails or screws.

For concrete or similar surfaces:

• Concrete nails are recommended for best results.

• Double-sided tape, hot glue, or a strong spray adhesive may be used if the floor is thoroughly cleaned and the Cable

Fixing Strips are cleaned to remove any oils.

• If spray adhesive is used, be sure to carefully follow all of the manufacturer’s instructions. WarmlyYours recommends

applying the spray adhesive to both the back of the Cable Fixing Strip and the floor.

Nail

Screw

14

Figure 6. Securing the Cable Fixing Strips