5.5.4 Instructions for Installation Under Tile and Stone Flooring

Option 1: Single-layer method for tile and stone

Apply a layer of 3/8 inch latex-modified thinset cement or self-leveling underlayment (SLU) over the heating cable. Lay the

tile or stone directly into that layer of thinset cement.

OR

Option 2: Double-layer method for tile and stone

Embed the heating cable in a skim coat of latex-modified thinset or self-leveling underlayment, completely covering the

heating element and the sensor wire. Apply a second layer of thinset and lay tiles as usual. The recommended depth for

both layers of thinset or SLU is 3/8 inch.

The single-layer method is used most by experienced installers in small applications with easy access. WarmlyYours does

NOT recommend the single-layer method for installing mosaics or tiles of different sizes or if you have not installed an

electric radiant heating system under tile or stone before.

Waiting Period: Regardless of method used, installation of floor heating cable under tile or stone requires 2 to 28 days

for the latex-modified thinset or self-leveling underlayment to cure. Follow manufacturer recommendations for cure times

applicable to your installation.

IMPORTANT: Do NOT turn on the WarmlyYours TempZone™ Floor Heating Cable (Twin) system until after the

thinset or self-leveling underlayment (SLU) has fully cured. Doing so will result in damage to the system

and cause the thinset or SLU to become brittle. Failure of the thinset or SLU may cause damage to the

embedded cable. This type of damage is not covered by the WarmlyYours warranty.

5.5.5 Instructions for Installation Under Carpet (U.S. only), Vinyl, or

Laminated Flooring

Before applying SLU, ensure that the cable is firmly secured to the subfloor to prevent it from floating to the top of the self-

leveling underlayment. Attach Circuit Check™ or PowerMan™ at this time. Cover cable with 3/8 inch layer of self-leveling

underlayment.

17

Advertising