Rev. 3.02

- 39 -

SRP-270

5. Disassembly and Assembly

5-1 General Precautions on Disassembly


This chapter describes the Disassembly and Reassembly procedures for the Printer of SRP-270 Series.
This Printer contains electronically sensitive device. Use caution when handling any component.

Whenever servicing the machine, you must perform as follows:

1. Disconnect the DC power jack of Adapter from the Printer before Disassembling.
2. Use a flat and clean surface.
3. Replace only with authorized components.
4. Do not force to remove plastic-material components.
5. Make sure all components are in their proper position.


5-2 Plate Bottom


1. Remove four screws securing the Plate Bottom.

Separate the Plate Bottom from the Lower Case.

3. Unplug Auto Cutter wire and FPC Cable from

the Main PCB.



2. If you want to remove the PCB Cover, remove

screw securing, as shown below.