Troubleshooting Guide

The light curtain carries out an internal self-test after startup. If an
error occurs, an appropriate signal combination is indicated by
the LEDs of the transmitter or the receiver.

System Status Indicators

Figure 19: LED indicators

Possible errors and operation status are indicated with the LED
indicators on the transmitter and receiver.

The following combinations are relevant:

Table 1: Transmitter

Table 2: Receiver

External error: An external interface error can be resolved by
correcting the installation, due to

1. Receiver: short circuit of both OSSDs, of OSSD to U

sp,

or of

OSSD to GND

2. Transmitter: Test input open

3. No power or power supply too low

4. Inadequate adjustment of transmitter and receiver

Internal error (orange Power LED is irregularly flashing): Exchange
Component

Status

Orange

(Power)

LEDs

Green

(ok)

Red

(Test)

No power supply (external)

off

off

off

Test input closed (external)

on

on

off

Test input open (external)

on

off

on

Controller error (internal)

flashing

off

on

Protective field error (internal)

flashing

off

on

ATTENTION

Assure that all power to the machine, and
safety system is disconnected during
electrical installation.

POWER

Transmitter

Power on

(orange)

POWER

Receiver

Power on

(orange)

Output active

(green)

Output inactive

(red)

OK

Normal operation

(green)

TEST

Test input

(red)

Optical

(IR light)

Optical

(IR light)

Status

Orange

(Power)

LED

Green

(Protective field

not interrupted)

Red

(Protective field

interrupted)

No power supply (external)

off

off

off

No sufficient power (external)

on

off

off

OSSD on (on-load operation, protective
field not interrupted, normal)

on

on

on

OSSD off (off-load operation, protective
field interrupted or insufficient
alignment of the system)

flashing

off

on

OSSD error (external, short circuit
between OSSD 1 and OSSD 2, towards
0 V or 24V DC)

all 3s

short time

off

flashing

Controller error (internal)

irregular

flashing

off

on

Protective field error (internal)

flashing

off

flashing

Normal operation

Transmitter

Receiver

Operation status

Test input closed
closed

OSSD on
OSSD off

Protective field free
Protective field interrupted

Test input open

OSSD off

Test active