Collect multi-channel measurements – Rockwell Automation 1441-DYN25-Z Dynamix 2500 Data Collector User Manual

Page 198

Advertising
background image

198

Rockwell Automation Publication 1441-UM001B-EN-P - September 2012

Chapter 6

Multi-channel Measurements

Collect Multi-channel Measurements

For multi-channel measurements, the cursor operates simultaneously on all
traces, even when hidden. This applies to adjustments using the Up and Down
arrows (amplitude axis), and the +/- adjusts the display/expand(frequency/time
axis).

See

Connector A and Connector B Inputs on page 19

for complete

information on the connectors and related channels.

Taking a two or more channel point requires two or more sensors, using
Connector A and B. A multi-channel measurement displays a spectral for each
channel. On the Offroute User screen, you can configure Offroute multichannel
measurements.

Follow these steps to take a multi-channel measurement.

1.

Connect the transducer and attach it to the correct location.

2.

Select the Display format as Spectrum or Time.

3.

Select the Input Channels X & Y & Z &R.

4.

Press Enter to start the measurement.

Advertising