Rockwell Automation 1336_S_F_T Allen-Bradley Dynamic Braking User Manual
Page 16
Heavy Duty Dynamic Braking
16
1336-5.64 — July, 2005
Table 1a
Maximum Ratings for 230V AC Drives, 375 Volts Turn-on Voltage
Table 2a
Maximum Ratings for 380-460V AC Drives, 750 Volts Turn-on Voltage
Table 3a
Maximum Ratings for 575V AC Drives, 937.5 Volts Turn-on Voltage
Dynamic Brake Module
Catalog No. 1336-MOD-
Resistance Value of Dynamic
Brake Resistor (Ohms)
Average Wattage Dissipation of
Dynamic Brake Resistor (Watts)
KA 005
28.0
666
KA 010
13.2
1650
Dynamic Brake Module
Catalog No. 1336-MOD-
Resistance Value of Dynamic
Brake Resistor (Ohms)
Average Wattage Dissipation of
Dynamic Brake Resistor (Watts)
KB 005
108.0
1500
KB 010
52.7
2063
KB 050
10.5
7000
Dynamic Brake Module
Catalog No. 1336-MOD-
Resistance Value of Dynamic
Brake Resistor (Ohms)
Average Wattage Dissipation of
Dynamic Brake Resistor (Watts)
KC 005
108.0
1500
KC 010
52.7
2063
KC 050
15.8
8000