Figure i-6 – Rockwell Automation 1336-SN-SP20A Snubber Board Kit User Manual

Page 13

Advertising
background image

1336-5.40 – August, 1999

I-13

4. Check for zero volts between +DC and -DC. Refer to Figure I-6.

Figure I-6
DC Voltage Check

5. Check for the absence of control voltage at:

TB20 and TB21 on drives using a PLC Comm Adapter Board

TB5, TB6, and TB7 on drives using a Standard Adapter
Board

6. Remove the customer-supplied wiring from the drive.

!

ATTENTION: A blown fuse can create a hazard of
shock which may result in death or serious injury. Check
voltage between the bus bar and both ends of all fuses.

AB0930

–DC (Negative
Capacitor Bus)

+DC

Check All Bus Fuses

Advertising