All parameters are specified at 12V, 4.5A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless noted otherwise.

8

Rockwell Automation Publication 1606-RM016A-EN-P — February 2014

Bulletin 1606 Switched Mode Power Supplies

8. Efficiency and Power Losses

AC 100V

AC 120V

AC 230V

Efficiency

typ.

84.1%

85.8%

87.6%

at 12V, 4.5A (full load)

Power losses

typ.

0.45W

0.5W

0.85W

at 0A

typ.

4.1W

3.9W

4.1W

at

12V,

2.25A

(half

load)

typ.

10.2W

8.9W

7.6W

at

12V,

4.5A

(full

load)

Fig. 8-1

Efficiency vs. output current at 12V,
typ.

Fig. 8-2

Losses vs. output current at 12V,

typ.

Efficiency

0

80

84

88

78

90%

4.5A

1

3

4

2

82

86

b

c

a

2.5

3.5

0.5

1.5

Output Current

a) 230Vac
b) 120Vac
c) 100Vac

Power Losses

0

4

8

0

12W

4.5A

0.5

1.5

1

2

6

b

c

a

10

2 2.5 3 3.5 4

a) 230Vac
b) 120Vac
c) 100Vac

Output Current

Fig. 8-3

Efficiency vs. input voltage at 12V,
4.5A, typ.

Fig. 8-4

Losses vs. input voltage at 12V, 4.5A,

typ.

Efficiency

85

120

155

190

225 260Vac

Input Voltage

89%

84

86

88

87

85

83

Power Losses

0

2

4

6

8

10

12W

85

120

155

190

225 260Vac

Input Voltage