2-4

Hardware Description

Digital Outputs

Five programmable solid state digital outputs are provided. Normally,
they are 24V DC outputs, but are convertible with a panel mounted
120V AC, I/O module. By default, they are connected to the internal
programmed logic software for the application specific design, but are
also programmable to any of the 16 Logic Status Bits. All five outputs
are LED indicated for high level visibility.

When used in a RTP application, the following outputs apply:

Digital Output 1 is normally the SPEED MATCH Output.

Digital Output 2 is normally the READY Output.

Digital Output 3 is normally the BELT EMERGENCY
BRAKE Output.

The final two outputs are normally not wired to interconnecting
circuitry, but instead are used as additional aids for setup and
troubleshooting.

Digital Output 4 is normally the Dancer center position logic.

Digital Output 5 is normally the Dancer web out position
logic.

Connector J3 is used to complete the interconnection for the digital
outputs between the Adapter Board and the Terminal Block (TB-3),
which is used to make the external connections.

J3-09 to TB3-54 Digital Output 1

J3-08 to TB3-55 Digital Output 2

J3-07 to TB3-56 Digital Output 3

J3-06 to TB3-57 Digital Output 4

J3-05 to TB3-58 Digital Output 5

J3-02 to TB3-61 +24V DC ISOL

J3-01 to TB3-62 24V DC COMMON

Advertising