Chapter 2 Time Recorder Extension Module

Recorder Status Indicators

The Recorder status indicators, located at the top of the Dynamix 2500 data
collector, operate differently in the Time Recorder module.

Table 3 - Recorder Status Indicators

Status
Indicator

State

Definition

Red

Solid

An error condition has occurred for the current block of
data. The status indicator turns off when the error
condition disappears.

Amber

Solid

An error has occurred during the recording. The status
indicator remains solid even when the error condition
disappears.

The recorded .csv file also contains a flag indicating that
the corresponding .wav file may contain flawed data.

Green

Flashing Green

The status indicator toggles on/off for each new data
block.