System Events

The MegaDySC tracks all operational alarms. These “System Events” are
classified into five groups based on severity, as listed in the following table.

System Event Log

The “System Event Log” screen displays a list of the last 40 system faults in
chronological order (See

Figure 16

). You can access this screen by pressing the

“System Events” button in the menu.

Figure 16 - System Event Log

The left side of the screen contains the list of system events, which are identified
by these fields:

Use the up/down arrows to navigate through the list. Detail for the currently
selected event is shown to the right of the list.

Severity

Description

Informational

Purely informational. No action is required.

Auto-Resetting

The DySC will reset within 60 seconds. No user action is required.

User Attention

User action may be required to correct a problem. The DySC will reset 60
seconds after the error condition is corrected.

Manual-Reset

For system events that force an automatic transfer to mechanical bypass, a
manual reset of the DySC system will be required.

Call Service

For events classified as Call Service, factory trained service support will be
required.

Description

Function

#

Unique ID within the list identifying each system event

Time

Start time of the fault.

Name

Name and description of the alarm.