1-6

Contactor Product Description

1502-UM050D-EN-P – June 2013

Contactor Specifications

Contactor Ampere Rating

400A

Continuous current rating

...................................

400 amps

Maximum rated voltage .............................................

7.2 kV

Maxium ambient temperature (for rated current) ......

40°C (104°F)

Frequency rating ........................................................

50/60 Hz

Short circuit interruption current rating:

– 1500 V to 5000 V (RMS sym.) ........................

6300 amps

– 7200 V (RMS sym.) ................................................

6000 amps

Short circuit withstand at rated voltage .....................

60 kA peak

Dielectric voltage withstand (for 60 seconds) ...........

18.2 kV/20 kV (IEC)

Make & break capability at rated voltage ..................

4.0 kA

Short time capability (for 1 second) ..........................

6.0 kA

(for 30 seconds) .........................

2.4 kA

Basic Impulse Level (B.I.L.) withstand

...............

60 kV

Mechanical life (operations):

– electrically held ................................................

2,500,000

– mechanical latch ...............................................

100,000

Electrical Life (operations)

.................................

1,000,000

Standard altitude rating ..............................................

1000 m (3,300 ft)

Max. altitude limit with spring replacement ..............

5000 m (16,500 ft)

Chopping current (average RMS) ..............................

0.5 amps

Switching frequency:

– electrically held ................................................

600 ops/hr

– mechanical latch ...............................................

150 ops/hr

Coil inrush current:
• At 120 VAC:

– electrically held ................................................

7.3 amps

– mechanical latch ...............................................

11.5 amps

• At 230 VAC:

– electrically held ................................................

8.3 amps

– mechanical latch ...............................................

N/A

™

The continuous current rating and B.I.L. withstand are de-rated for altitudes above 1000 m (3300 ft).

Refer to Altitude Adjustment in Chapter 4 for details.

IEC rating at 7200 V (RMS sym.) – 5300 amps.

Provided routine maintenance is performed as detailed in this manual.