Mold Pressure Module

Publication 1746-5.13 July 1998

11. Listing of M0/M1 file words

You load M0/M1 file data into the module from your PC equipped with

DARTwin software. M0 and M1 files contain:

module configuration data, loaded by DARTWin software (words 0-48)

summary data processed by the module (words 49-106)

Summary data (in units of A/D counts x 1/100 sec.) is stored in two frames:

frame 1 = words 49-75

frame 2 = words 76-106

Important:

See summary data notes on page 18.

Address (e = module slot number)

Description

Module Config Data
Channel 1 (M0)

Channel 2 (M1)

M0:e.0, 2, 4, 6

M1:e.0, 2, 4, 6

Dead time, trigger ON (for triggers 1, 2, 3, 4)

M0:e.1, 3, 5, 7

M1:e.1, 3, 5, 7

Dead time, trigger OFF (for triggers 1, 2, 3, 4)

M0:e.8

M1:e.8

Alarm control word (enable/disable)

M0:e.9

M1:e.9

Alarm level, cycle time low

M0:e.10

M1:e.10

Alarm level, cycle time high

M0:e.11

M1:e.11

Alarm level, peak high

M0:e.12

M1:e.12

Alarm level, peak low

M0:e.13

M1:e.13

Alarm level, peak time high

M0:e.14

M1:e.14

Alarm level, peak time low

M0:e.15, 17, 19, 21

M1:e.15, 17, 19, 21

Alarm level, trigger time low (triggers 1, 2, 3, 4)

M0:e.16, 18, 20, 22

M1:e.16, 18, 20, 22

Alarm level, trigger time high (triggers 1, 2, 3, 4)

M0:e.23

M1:e.23

Alarm level, minimum in frame, low

M0:e.24

M1:e.24

Alarm level, minimum in frame, high

M0:e.25, 26

M1:e.25, 26

Alarm level, peak integral low

M0:e.27, 28

M1:e.27, 28

Alarm level, peak integral high

M0:e.29, 30

M1:e.29, 30

Alarm level, trigger 1 integral low

M0:e.31, 32

M1:e.31, 32

Alarm level, trigger 1 integral high

M0:e.33, 34

M1:e.33, 34

Alarm level, trigger 2 integral low

M0:e.35, 36

M1:e.35, 36

Alarm level, trigger 2 integral high

M0:e.37, 38

M1:e.37, 38

Alarm level, trigger 3 integral low

M0:e.39, 40

M1:e.39, 40

Alarm level, trigger 3 integral high

M0:e.41, 42

M1:e.41, 42

Alarm level, trigger 4 integral low

M0:e.43, 44

M1:e.43, 44

Alarm level, trigger 4 integral high

M0:e.45, 46

M1:e.45, 46

Alarm level, frame integral low

M0:e.47, 48

M1:e.47, 48

Alarm level, frame integral high