Mold Pressure Module

5

Publication 1746-5.13 July 1998

3. Module I/O

Inputs

The module has two independent channels that you configure to process

signals from machine sensors (default) or from the SLC output image table

across the backplane. Types of machine sensors include::

Outputs (Summary Data)

The module processes a frame of summary data for each molding cycle,

and alternately makes available the previous frame for display. It does this

for channels 1 and 2. Your ladder logic can read summary data from the

module’s M0/M1 files. You can observe summary data displayed on a PC

equipped with DARTWin software. The PC must be linked to the module

with DARTNet network from RJG Technologies, Inc.
A list of summary data follows. For a complete list with word addresses,

see the M0/M1 File Listing in section 11.

level:

range

application:

low

2mV/V sensitivity

mold pressure

4-20mA

general purpose

-100 to +100mV

bi-directional

high

0-10V

hydraulic pressure

Summary Data Displayed on Your PC and Read by SLC in M0/M1 Files
injection cycle time
peak injection pressure
minimum cycle pressure
time to peak pressure
trigger time (off to on to off) for T1 (injection forward - fill, pack, and hold)
trigger time (off to on to off) for T2 (fill)
trigger time (off to on to off) for T3 (screw backup)
trigger time (off to on to off) for T4 (mold closed)
integral to peak pressure in units of PSIxSec
integral of trigger 1 (injection forward) in units of PSIxSec
integral of trigger 2 (fill) in units of PSIsec
integral of trigger 3 (screw backup) in units of PSIxSec
integral of trigger 4 (mold closed) in units of PSIxSec
integral of injection cycle in units of PSIxSec