Installing the 1779ĆKP5 Module

Chapter 3

3Ć5

There are three sets of switches (labeled S-2, S-4, and S-5) on the
1779-KP5 host board. Use the following procedure to access these
switches:

CAUTION: Electrostatic discharge can degrade performance or
cause permanent damage to the module. To minimize or
prevent electrostatic discharge damage, handle the module at a
static-safe workstation.

If a static-safe workstation is not available, touch and remain in contact
with a grounded object to discharge yourself while handling the module.

1.

Make sure that you remove all power to the module. Usually, you
remove power to the 1779-KP5 by locking open the main disconnect
switch on your enclosure.

2.

Loosen the four fasteners on the front panel of the module. Pull the
removable frame out to the switch-setting position. This exposes the
switch assemblies.

Dip Switches

S2

S4

S5

Removable Frame

16010