background image

Industrial 14” CRT Monitors

20

Publication 6156-2.0

Fuse replacement

Bulletin 6156 Industrial Monitors are equipped with an AC line fuse,
which is accessible from the rear panel. To replace the fuse:

1. Remove AC power by disconnecting the AC line cord.

2. Use a flat blade screwdriver to unscrew the cap on the fuse

holder.

3. Remove the cap and fuse.

4. Replace the fuse with a 5ST Slo-Blo type rated at 2.5A, 250VAC.

5. Secure the fuse holder cap with the screwdriver.

6. Restore AC power.

Cleaning instructions

To clean the monitor screen protector, use a 50% solution of alcohol
(ethanol or isopropyl) in water on a cotton gauze pad or soft cotton
cloth. Paper products may scratch the surface, and should be
avoided.

Note: The solvent should be applied only to the cloth, and not
directly to the surface to be cleaned.