5. Insert the monitor in the panel cutout from the front of the panel.

Be careful not to damage the threaded mounting studs as you
position the monitor.

6. Secure the unit with the locknuts and washers provided. Tighten

evenly to 25 inch-pounds of torque.

Important: To assure a proper seal, be sure to install a washer
and nut on each of the 14 mounting studs.

!

ATTENTION: Mounting nuts must be tightened to a
torque of 25 inch-pounds to provide panel seal and
avoid potential damage to the Bulletin 6156 Industrial
Monitor. Allen–Bradley assumes no responsibility for
water or chemical damage to the Bulletin 6156
Industrial Monitor or other equipment within the
enclosure due to improper installation.

7. Remove the protective adhesive sheet from the screen of the

Industrial Monitor. The sheet is designed to prevent scratching of
the polycarbonate screen protector or the optional touchscreen
during shipping and installation. It should be removed before use.