1336 plus, Force and impact filter installation, Plus – Rockwell Automation 1305 RFI Filter PLUS,PLUSII,FORCE,IMPACT Installation User Manual

Page 7

Advertising
background image

Input RFI Filters

5

1336 PLUS,

PLUS

II,

FORCE and

IMPACT Filter Installation

Use the cross reference below to verify that the correct filter has been
selected for your CE compatible drive. In addition, ensure that the
drive was ordered with the “-AE” enclosure option or the EMC
Enclosure Kit (1336x-AEx) has been properly installed.

Filter Selection

Components Included with Filter

Filter Catalog
Number

Filter
Series

Mounting

See . . .
(pg. 11-13)

Power
Diss.
(Watts)

Three-Phase
Volts

Used with . . .

Frame
Reference

1336 PLUS/

PLUS

II

1336 FORCE

1336 IMPACT

1336-RFB-7-AA

A

Figure 1

4.5

200-240V

1336S/F-AQF05 - AQF10

N/A

1336E-AQF05 - AQF10

A1

380-480V

1336S/F-BRF05 - BRF20

1336E-BRF05 - BRF20

A1-A2

1336-RFB-7-A

B

Figure 1 or
Figure 2

2

200-240V

1336S/F-AQF05 - AQF10

1336E-AQF05 - AQF10

A1

380-480V

1336S/F-BRF05 - BRF20

1336E-BRF05 - BRF20

A1-A2

1336-RFB-16-AA

A

Figure 1

9

200-240V

1336S/F-AQF15 - AQF20

1336E-AQF15 - AQF20

A2

380-480V

1336S/F-BRF30 - BRF50

1336E-BRF30 - BRF50

A2-A3

1336-RFB-16-A

B

Figure 1 or
Figure 2

9.5

200-240V

1336S/F-AQF15 - AQF20

1336E-AQF15 - AQF20

A2

380-480V

1336S/F-BRF30 - BRF50

1336E-BRF30 - BRF50

A2-A3

1336-RFB-30-A

A

Figure 1

14

200-240V

1336S/F-AQF30 - AQF50

1336E-AQF30 - AQF50

A3

1336-RFB-30-A4

A

Figure 2

35

380-480V

1336S/F-BRF75 - BRF200

1336E-BRF75 - BRF100 A4

1336-RFB-27-B

A

Figure 2

30

200-240V

1336S/F-A007

1336T-A001 - A007

1336E-A007

B

380-480V

1336S/F-B007 - B015

1336T-B001 - B015

1336E-B007 - B015

B

1336-RFB-48-B

A

Figure 2

56

200-240V

1336S/F-A010 - A015

1336T-A010 - A015

1336E-A010 - A015

B

380-480V

1336S/F-B020 - B030

1336T-B020 - B030

1336E-B020 - B030

B

1336-RFB-80-C

A

Figure 2

71

200-240V

1336S/F-A020 - A030

1336T-A020 - A030

1336E-A020 - A030

C

380-480V

1336S/F-BX040 - BX060

1336T-BX040 - BX060 1336E-BX040 - BX060

C

1336-RFB-150-D

A

Figure 3 or
Figure 4

90

200-240V

1336S/F-A040 - A050

1336T-A040 - A050

1336E-A040 - A050

D

380-480V

1336S/F-B060 - B100

1336T-B060 - B100

1336E-B060 - B100

D

1336-RFB-180-D

A

Figure 3 or
Figure 4

125

200-240V

1336S/F-A060

1336T-A060

1336E-A060

D

380-480V

1336S/F-B125 - BX150

1336T-B125 - BX150

1336E-B125 - BX150

D

1336-RFB-340-E

A

Figure 3 or
Figure 4

60

200-240V

1336S/F-A075 - A125

1336T-A075 - A125

1336E-A075 - A125

E

380-480V

1336S/F-B150 - B250

1336T-B150 - B250

1336E-B150 - B250

E

1336-RFB-475-G

A

Figure 5

61

380-480V

1336S/F-BP250 - BP350
1336F-BPR250 - BPR350

N/A

1336E-BP300 - BP350
1336E-BPR300 - BPR350

F

1336S/F-BX250 - B350

1336T-BX250 - B350

1336E-BX250 - B350

G

1336-RFB-590-G

A

Figure 5

94

380-480V

1336S/F-BP400 - BP450
1336F-BPR400 - BPR450

N/A

1336E-BP400 - BP450
1336E-BPR400 - BPR450

F

1336S/F-B400 - B450

1336T-B400 - B450

1336E-B400 - B450

G

1336-RFB-670-G

A

Figure 5

121

380-480V

1336S/F-B500 - B600

1336T-B500 - B600

1336E-B500 - B600

G

Item

Quantity - 1336-RFB- . . .

7-A, 16-A, 30-A

30-A4, 27-B, 48-B, 80-C

150-D, 180-D, 340-E

475-G, 590-G, 670-G

Filter

1

1

1

1

EMT Conduit

1

1

EMT Conduit Fitting

1

2

Bolts

4

8

3

Flat Washers

4

Star Washers

4

Terminal Block Housing

1

Standoffs

2

Nuts

3

4

3

E

ng
lis

h

Advertising
This manual is related to the following products: