9 measuring gas pressure – Bosch 250 SXO NG User Manual

Page 12

Advertising
background image

6 720 607 440

12

Appliance details

2.9

Measuring gas pressure

2.9.1

Connecting Manometer

B

Shut off gas.

B

Remove front cover and locate inlet gas pressure
measuring point (see Fig. 14).

B

Loosen screw inside test point fitting (do not remove)
and connect manometer tube on test point.

2.9.2

Static Pressure Test

B

Turn gas supply back on.

B

Operate all other gas appliances on same gas piping
system at maximum output.

B

Record static gas pressure reading in table 3.

2.9.3

Operating Pressure Test

B

ON/OFF switch in position OFF (0).

B

Press and hold "Program" (M) button and turn ON/
OFF switch to ON position.

Fig. 13
B

As soon as '188' is displayed, release "Program"
button and the display should read P2.

B

Press

, until P1 appears.

Note: While in this mode the appliance will run
constantly at maximum power and allow maximum water
flow. These program modes are for test purposes only
and not intended for normal operation.
B

Turn on high volume of hot water flow (at least 6
gpm) and heater will ignite.

B

Record operating gas pressure reading in table 3.

Gas pressures lower than 5" W.C. for Natural Gas or
11" W.C. for LPG will result in insufficient degree rise
to the hot water being used, and must be corrected.
See Gas Connections, chapter 2.8.

Fig. 14 Gas pressure measuring (left tapping)

HIGH ALTITUDE OPERATION

Static Gas Pressure Reading (see Chapter 2.9)
enter here: ___________________

Operating Gas Pressure Reading (see Chapter 2.9)
enter here: ___________________

Table 3

Altitude

Natural

Gas:

Liquid

Propane:

0 - 4,000 ft

(0 - 1,219 m)

no

modification

no

modification

For operation at

elevations

above 2,000 ft

(610 m) the

equipment

ratings shall be

reduced at the

rate of 4% for

each 1,000 ft

(305 m) above

sea level

4,000 ft - 7,000 ft

(1,219 m - 2,134 m)

CO

2

adjustment with flue

gas analyzer required See

chapter

9

for instructions.

Above 7,000 ft

(above 2,134 m)

Not approved

Table 4

Advertising