Special adjustment for measuring and adjusting CO2 levels

D. Returning to Service:
1. Return slotted cover to original position.
2. Reinstall Torx cover.
3. Remove CO

2

analyzer probe and reinstall plug in

exhaust collar.
4. Turn ON/OFF switch to the OFF (O) position and
then back to the ON (I) position.
5. Heater is ready for normal operation.

Final Readings
P2 CO

2

Reading:

% CO

2

P1 CO

2

Reading:

% CO

2

Fig. 37

Fig. 38

Without Front

Cover

With Front

Cover

Nat. Gas

Nat. Gas

max. input

P1

9.1

± 0.1 %

9.7

± 0.1 %

min. input

P2

9.4

± 0.1 %

9.7

± 0.1 %

LP Gas

LP Gas

max. input

P1

10.1

± 0.1 %

10.7

± 0.1 %

min. input

P2

10.4

± 0.1 %

10.7

± 0.1 %

* Final reading must be confirmed with the front cover
on, CO

2

levels increase when the cover is installed.

Table 7