Bendix Commercial Vehicle Systems BA-922 COMPRESSOR User Manual

Page 17

Advertising
background image

17

Symptom:

What it may indicate:

What you should do:

(e) Air compressor discharge and/or

air dryer inlet temperature too

high.

(f) Insufficient coolant flow.

(g) Restricted discharge line.

Check temperature as outlined in Test 3 on

page 24. If temperatures are normal go to

4.0(h).

Inspect coolant line. Replace as necessary

(I.D. is 1/2").

Inspect the coolant lines for kinks and

restrictions and fittings for restrictions.

Replace as necessary.

Verify coolant lines go from engine block to

compressor and back to the water pump.

Repair as necessary.

If discharge line is restricted or more than

1/16" carbon build up is found, replace the

discharge line. See Table A, column 2, on

page 13 for recommended size. Replace

as necessary.

The discharge line must maintain a

constant slope down from the compressor

to the air dryer inlet fitting to avoid low points

where ice may form and block the flow.

If, instead, ice blockages occur at the air

dryer inlet, insulation may be added here,

or if the inlet fitting is a typical 90 degree

fitting, it may be changed to a straight or

45 degree fitting. For more information

on how to help prevent discharge line

freeze-ups, see Bendix Bulletins TCH-08-

21 and TCH-08-22 (Appendix B). Shorter

discharge line lengths or insulation may be

required in cold climates.

Temperature

Other

Check compressor air inlet line for restric-

tions, brittleness, soft or sagging hose

conditions etc. Repair as necessary. Inlet

line size is 3/4 ID. Maximum restriction

requirement for compressors is 25 inches

of water.

Check the engine air filter and service if

necessary (if possible, check the air filter

usage indicator).

(h) Restricted air inlet (not enough air

to compressor).

(g)

4.0 Oil in Supply

or Service

Reservoir*

(air dryer installed)

(continued)

Kinked discharge line shown.

Partly

collapsed

inlet line

shown.

Testing the temperature

at the discharge fitting.

Inspecting the coolant hoses.

*If a maintained Bendix

®

PuraGuard

®

system filter or Bendix

®

PuraGuard QC

oil coalescing

filter is installed, call 1-800-AIR-BRAKE (1-800-247-2725) and speak to a Tech Team member.

(g)

(e)

(f)

(h)

Advertising