Electrical requirements j1939 – Bendix Commercial Vehicle Systems VORAD VS-400 SYSTEM INSTALL GUIDE User Manual

Page 28

Advertising
background image

27

Electrical Requirements

J1939

Note:

The J1939 data bus uses two (2) 120-ohm resistors to terminate each end of the data bus on the vehicle. These resistors must

remain in place for proper data bus communication. Due to the mounting location of the Forward Looking Radar, the closest of the
vehicle's J1939 terminators may have to be relocated nearer the radar as shown in the diagram below. Check the resistance of the
data bus using an ohmmeter before and after adding any device to the bus. With the ignition key in the OFF position, the resistance
of the data bus should read approximately 60-ohms (120 / 2).

Note:

The illustration above shows J1939/11, however J1939/15 (2-wire) can be used.

Pin #

Description

J1-3

J1939_SHIELD

J1-4

CAN_HI

J1-5

CAN_LO

Terminating

resistor

J-1939/11 data link

(OEM supplied)

GND

+

_

Shield

termination

Terminating

resistor

5
4
3

J1

Advertising