39

Appendix

SAE J1939/11 Recommended Cable Termination Procedure

1. Remove cable outer jacket approximately 1" (25mm).

2. Remove foil from exposed wires to within 1/16" (2mm) from cable jacket.

3. Strip insulation from data wires .25" (7mm).

4. Attach extended wire barrel socket contact to the drain wire or attach adhesive fi ller solder sleeve and wire to drain wire per

manufacturer's recommendations. For the solder sleeve option, cut the wire on the solder sleeve to a length of 1" (25mm) and
strip the insulation back .25" (7mm).

5. Crimp the appropriate terminal on each data wire and solder sleeve wire or the extended socket per the manufacturer's

recommendations.

6. Slide the adhesive fi ller shrink tube over the cable end.

7. Install the terminals into the connector body per the manufacturer's instructions.

8. Install the wedge in the front of the connector body per the manufacturer's instructions.

9. Apply the shrink tube to the end of the connector body per the manufacturer's instructions.

Solder Sleeve
with Wire

Extended Socket

Cable

Drain Wire

Shrink Tube

Data Wires

Terminals

Plug

Wedge

Final Assembly

OR

Advertising