Troubleshooting Diagnostic Trouble Codes:

Yaw Rate Sensor (YRS)

(continued)

Yaw Rate Sensor Tests
1.
Measure resistance between input voltage and ground

at the sensor wiring harness connector.

Test

Measurement

Power and Ground Input

8 to 16 volts

1 = Power Input

2 = Ground Input

2. Verify wiring between the Yaw Rate Sensor and the

ECU.

SAS Wire Harness

ECU Wire

Measurement

Terminal

Harness Terminal

4

7

Verify Continuity

3

8

Verify Continuity

Looking into wire harness connector

3. Verify wiring between the Yaw Rate Sensor and power/

ground.

SAS Wire Harness Terminal

Measurement

4 to Voltage & Ground

Verify open circuit (no continuity)

3 to Voltage & Ground

Verify open circuit (no continuity)

4. To perform a calibration procedure of the Yaw Rate

Sensor, ACom

Diagnostics V4.0 is required. Using

the program, select the “Configuration” option, followed

by the “Calibrate” option. The following screen should

be displayed.

5. Follow the prompts to perform a calibration of the Yaw

Rate Sensor.

6. To test the Yaw Rate Sensor, ACom V4.0 is required.

Using Bendix ACom V4.0, select the “Component Test”

option, followed by the “ESP Test” option. The following

screen should be displayed.

7. Follow the prompts to perform a test of the Yaw Rate

Sensor.