Bird Technologies 429-83H-01 Series-Manual User Manual

Page 11

Advertising
background image

TX RX Systems Inc. Manual 7-9439-6 09/03/09 Page 3

The quad-amplifier in the tower top box amplifies
the weak received signal before the signal enters a
long and lossy transmission line, thus preventing
the line loss from degrading the signal-to-noise
ratio. The quadrature amplifiers have a separate
power circuit for each half of the amplifier which
provides component redundancy as well as unsur-
passed IM performance. Microprocessor controlled
fault detection circuitry in the tower top box pro-
vides continuous monitoring and switching of each
quad amplifier while sending operational data to
the base unit front panel for at-a-glance status
reporting and form-C contact switching for alarm
integration. Included in the tower top box is a pre-

selector filter, amplifier “A” and amplifier “B,”
switching circuitry, control board and PolyPhaser
surge suppressors (see Figure 1). The specifica-
tions for the tower box are listed in Table 2.

The ground-mounted MCU shown in Figures 2A
through 2C
is intended for 19-inch rack mounting.
It houses amplifier and signal distribution assem-
blies, alarm indicators, a power supply or DC-DC

Electrical Specifications

Frequency Range

792 to 824 MHz

Net Gain

23 dB

Noise Figure (typ /max)

2.7 / 3.0 dB

Backup Amplifier Switching

Solid State RF Switch

Integrated Test Port
Isolation

45 dB

Preselector Type

Loss
Rejection

7-pole TEM Bandpass

with cross-couplings

<0.8 dB

>60 dB @ 776 and 851 MHz

LNA Type

Gain
Noise Figure
3rd Order Input IP

2-stage Quadrature

integrated into filter

26 dB

1.2 dB

18 dBm

Impedance

50 Ohms

Antenna Port VSWR

2 : 1

Power Requirements

12 VDC @ 1.25 A

Lightning Protection

Impulse Suppressor on all

external connectors

Operating Temp Range

-30° C to +60° C

Mechanical Specifications

Enclosure

Modified NEMA 4x:

Stainless steel

weather resistant

Connectors

N -female

Dimensions (HWD)
not including mounting tabs
and connectors

18” x 6” x 6”

(457 x 152 x 152 mm)

Net Weight

20 lbs (9.1 kg)

Table 2: Tower box specifications. Values are typical unless

noted otherwise.

Electrical Specifications

Frequency Range

792 to 824 MHz

Multicoupler Net Gain

+1 dB typ; 0 dB min

Distribution Amp Type
Gain
Noise Figure
1 dB compression point
3rd Order Output IP

Quad-Coupled dual stage

23 dB

4 dB

27 dBm
46 dBm

Number of Outputs
Split Loss

16 or 32

18 dB

Impedance

50 Ohms

VSWR

<2 : 1

Connectors
to TTA
to BTS
Test Port input

N - Female

BNC - Female
BNC - Female

TTA NET GAIN
electronic attenuator

0 to 15.5 dB

in 0.5 dB steps

DISTRIBUTION
electronic attenuator

0 to 3 db

in 0.5 dB steps

Alarm / Warning Contacts

Two Form-C Contacts

Nominal 2A @ 30 VDC

or 0.5A @125 VAC

I/O

Ethernet

Power Requirements

Model 429-83H-01-M
Model 429-83H-01-M-48

90 - 240 Vac @ 50/60 Hz

-48VDC

Operating Temp Range

0° C to + 50° C

Mechanical Specifications

Enclosure

Standard EIA 19” Rack Mount

Dimensions (HWD)

1 RU x 19” x 14”

(38 x 483 x 356 mm)

Net Weight

10.5 lbs (4.8 kg)

Table 3: Multicoupling Unit specifications. Values are

typical unless noted otherwise.