Bird Technologies 429-83H-01 Series-Manual User Manual

Page 20

Advertising
background image

TX RX Systems Inc. Manual 7-9439-6 09/03/09 Page 12

shipped from the factory along with the
tower top box.
Refer to Figure 12. The chas-
sis of the lightning arrester should be connected
to the master ground bus with a pigtail.

Installing the MCU

The MCU is designed for indoor mounting in a
common 19-inch relay rack or cabinet. The follow-
ing steps are required for proper installation.

1) Install the MCU into the rack or cabinet with four

mounting screws from the hardware kit (part #
3-16509) which is included with your shipment.
Make sure you use a nylon washer under the
head of the screws in order to protect the front
panel. Torque the mounting screws to no more
than 15 in/lbs. Over tightening the mounting
screws may damage the front panel.

2) Connect the MCU ground lug to the Equipment

Rack Master Ground Bar with a pigtail.

3) Connect the main and test transmission cables

to the appropriate connectors at the back of the
unit.

Figure 11: Application of rubber splicing tape. Note: Additional waterproofing protection can be realized by
covering the rubber tape with either “Scotch Kote” or Vinyl Plastic Electrical Tape (“Scotch” brand 33+).

Test

Line

Antenna

Feedline

Main

Transmission

Line

Ground Lug

Moisture

Vent

Figure 12: Lightning arrester TXRX part # 8-21550.
This device must be connected to the master ground
buss with a pigtail.

RF In

from

Tower Top

RF Out

to MCU

CAT-5e

Cable

Here

Advertising