Controller cards, T1 controller card, Quick start – Black Box COMPACT T1 User Manual

Page 34: Dip switches

Advertising
background image

30

Compact T1 - Release 6.1

Quick Start

Controller Cards

Controller Cards

T1 Controller Card

Dip Switches

On the front of the T1 Controller card on the Compact T1 are DIP switches used to
configure the Compact T1 locally.

Switch Function Description

ACO

Alarm Cut
Off

0 = Alarm contacts enabled (close when alarm occurs). Default.
1 = Alarm contacts disabled (open).

ST

Self Test

0 = Normal operation. Default.
1 = Perform Self Test.

OPT

Spare

RST

Reset

0 = User-configured operation. Default.
1 = Reset configuration to factory defaults, & reset CLI password

T1-1
T2-1

Line
Coding

0 = B8ZS. Default.
1 = AMI

T1-2
T2-2

Line
Loopback

0 = Loopback off. Default.
1 = Loopback on

T1 3-4
T2 3-4

Framing

0 = ESF (Extended Superframe). Default.
1 = D4

T1 5 - 6
T2 5 - 6

Signaling

Switch 3

Switch 4

Switch 5

Switch 6

Setting

0

1

1

1

TR-08 A-Shelf with FDL, 16-bit Alarm
frame

1

0

0

0

TR-08 A-Shelf with FDL, 13-bit Alarm
frame

1

0

0

1

TR-08 A-Shelf with FDL disabled

1

0

1

0

TR-08 B-Shelf

0

0

0

0

Loop Start/Ground Start. Default.

0

0

0

1

E&M Immediate Start with ringback.
(used for D3 PLAR and DPT)

0

0

1

0

E&M Immediate Start with ringback and
Calling Party Disconnect (CPD)

Advertising