Calculated Industries 5060 User Manual

Page 10

Advertising
background image

8 — ElectriCalc Pro

NOTE: The temperature units can be
displayed in Celsius (°C) or Fahrenheit
(°F) by using the preference function
S ÷.

S 4 — Copper/Aluminum
Used to toggle between copper (de-
fault) and aluminum wire types. When
the wire type is revised, any calculated
wire size will be re-calculated automati-
cally. If a wire size is entered with the
wrong wire type, pressing

S 4 will

change the material type without
changing the size.
Displays: Al or Cu.

S 5 — Free Air (FrAir)
Sets calculator into Free Air mode,
which refers to NEC Table 310-17 for
wire size calculations. Displays: FrAir.
S 6 — 60°C Wire Insulation
Sets calculator to 60°C wire insulation
type for wire size calculations. This is
the default setting.
Displays: 60.

S 7 — 75°C Wire Insulation
Sets calculator to 75°C insulation type
for wire size calculations.
Displays: 75.