C7420 fiber c/port and f6150–160 fiber transceiver, Electromagnetic compatibility (emc), Emissions (radio frequency interference) – ClearCube C/Port & MVX User Manual

Page 56: Electro-magnetic interference (emi) immunity

Advertising
background image

46 •

Regulatory Compliance

C7420 Fiber C/Port and F6150–160 Fiber Transceiver

ElectroMagnetic Compatibility (EMC)

The statements contained within this section are limited to the C7420 Fiber C/Port and

F6150–160 fiber transceiver. Regulatory compliance specifications for any other equipment

mentioned within this manual can be found in separate documentation.

Emissions (Radio Frequency Interference)

This equipment was tested in accordance with the procedures given in EN 55022 – Limits and

Methods of Measurements of Radio Interference Characteristics of Information Technology

Equipment. The equipment was found to be in compliance with the Class A limits per EN

55022: 1998, CISPR 22: 2002 and FCC 47 CFR – Part 15, Subpart B in both radiated and

conducted emissions. These limits are designed to provide reasonable protection against

harmful interference when the equipment is operated in an industrial or commercial

environment.

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing

Equipment Regulations ICES-003.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le

matériel brouilleur du Canada.

This equipment exhibits compliance to the Voluntary Control Council for Interference (VCCI)

Class A, ITE requirements in Japan.

Electro-Magnetic Interference (EMI) Immunity

This equipment was also tested in accordance with the procedures given in the EN 55024:

1998 – Information Technology Equipment, Immunity Characteristics – Limits and methods

of measurements and was found to comply with:

EN 61000-4-2: 1995, Electrostatic Discharge Immunity Test, performance criteria: 4/8 kV

EN 61000-4-3: 1995, Immunity to Radiated, Radio Frequency, Electromagnetic Fields,

performance criteria: 3 V/m

EN 61000-4-4: 1995, Electrical Fast Transient/Burst Requirements, performance criteria:

1 kV/.5 kV

EN 61000-4-5: 1995, Surge Immunity Requirements, performance criteria: 2/1 kV

EN 61000-4-6: 1996, Conducted Disturbance Induced by Radio-Frequency Fields

Immunity, performance criteria: 3 Vrms

EN 61000-4-8: 1994, Power Frequency Magnetic Field Immunity, performance criteria: 1

A/m

EN 61000-4-11: 1994, Voltage Dips, Short Interruptions and Voltage Variations Immunity,

performance criteria: 95%-5c and 250c, 30%-25s

Advertising