Step 5: Connecting supply

1. Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide

the valve bracket up until the larger cutout in the frame’s slot aligns with the screw head (see
Figure 5b). Then lift up to remove the valve bracket from the frame.

2 FOR HOT AND COLD SUPPLY: Attach the stop/check to the hot and cold water supply piping

from the wall. Connect the flexible hoses to the Vernatherm™ Mixing Valve and to the
check/stops (see Figure 5a).

NOTE: The “H” on Vernatherm™ Mixing Valve indicates hot water supply inlet.

FOR SINGLE TEMPERED SUPPLY: Attach the stop/check to the 1/2" tempered supply line.
Connect the stop/check to the tempered line adapter with the flexible supply hose (Figure 5c).

3. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2" drain

pipe stubbed out of the wall.

4. Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly into

place. Secure the stainer with the screw provided.

Figure 5a

FLEXIBLE SUPPLY

HOSE

VERNATHERM™

THERMOSTATIC

MIXING VALVE

FLEXIBLE

SUPPLY

HOSE

CONNECT TO
1/2" NPT HOT

WATER SUPPLY

CONNECT TO

1/2" NPT COLD

WATER SUPPLY

Figure 5c

FLEXIBLE

SUPPLY HOSE

(TO SOLENOID

BRACKET)

TO SUPPLY LINE

TEMPERED

LINE ADAPTER

(S39-685)

Hot and

Cold

Supplies

Single

Tempered

Supply

Figure 5b

SLOT IN

FRAME

VALVE BRACKET

MOUNTING SCREW