Express® Lavatory System - MG-Series with TouchTime® Control
MG-2/TT

Installation Instructions

6

2/8/07

Bradley Corporation • 215-1480 Rev. E; EN 06-915

Figure 1a

TAS - Texas Accessibility
Standards:
Juvenile Height (grades
Pre-K thru 5 or 6)

4"

(102)

5"

(127)

FLOOR

APPROX. DIMENSION

14"

(356)

14"

(356)

18-7/8"

(479)

24-3/4"

(629)

22-1/4"

(565)

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY – STUB OUT 2"

1-1/2" NPT DRAIN
STUB OUT 2"

3/8" WALL ANCHORS (8) PLACES MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR

CENTERLINE OF FIXTURE

21"

(533)

22-1/2"

(572)

28"

(711)

3-3/4" (95)

16"

(406)

4"

(102)

4" (102)

RECOMMENDED 240V/208V
OR 277V FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(2-1/2"l x 3"w x 4"h)

RECOMMENDED

240V/208V OR 277V

FOR OPTIONAL

ELECTRICAL BOX

LOCATION

(4"l x 3"w x 4"h)

19-1/2"

(495)

H

C

16-1/2"

(419)

25-1/2" (648)

APPROX. DIMENSION

25-1/2" (648)

A

A

B

B

B

B

B

B

Figure 1b

TAS - Texas Accessibility
Standards:
Juvenile Height (grades 6
thru 8 or 9)

4"

(102)

5"

(127)

FLOOR

APPROX. DIMENSION

14"

(356)

14"

(356)

26-3/4"

(679)

24-1/4"

(616)

1/2" NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY – STUB OUT 2"

1-1/2" NPT DRAIN
STUB OUT 2"

3/8" WALL ANCHORS (8) PLACES MIN. PULL-OUT STRENGTH 1000 LBS. PER ANCHOR

CENTERLINE OF FIXTURE

23"

(584)

3-3/4" (95)

18"

(457)

4"

(102)

4" (102)

RECOMMENDED 240V/208V
OR 277V FOR OPTIONAL
ELECTRICAL BOX
LOCATION
(2-1/2"l x 3"w x 4"h)

RECOMMENDED

240V/208V OR 277V

FOR OPTIONAL

ELECTRICAL BOX

LOCATION

(4"l x 3"w x 4"h)

21-1/2"

(546)

H

C

16-1/2"

(419)

25-1/2" (648)

APPROX. DIMENSION

25-1/2" (648)

A

A

B

B

B

B

B

B

30"

(762)

20-7/8"

(530)

24-1/2"

(622)

110V GFI
PROTECTED
ELECTRICAL
OUTLET

110V GFI
PROTECTED
ELECTRICAL
OUTLET