WARNING

Failure to follow this warning could result in personal injury,
death and/or property damage.
Never use a match or other open flame to check for gas leaks.
Use a soap-and-water solution.

FIRE OR EXPLOSION HAZARD

15. Reinstall vent connector on furnace vent elbow. Securely
fasten vent connector to vent elbow with 2 field-supplied,
corrosion-resistant, sheet metal screws located 1800 apart.
16. Replace blower access door only, if it was removed.
17. Set thermostat above room temperature and check
furnace for proper operation.
18. Verify blower airflow and speed changes between heating
and cooling.
19. Check for gas leaks.
20. Replace outer access door.

21. Turn on electric power and gas supply to the furnace.
22. Check furnace for proper operation. Refer to "Operational
Checks" section to verify burner flame characteristics.

пмтй Ю»º±®» Ô»¿ª·²¹ Я² Ч²-¬¿´´¿¬·±²

Verify cooling and fan only operation.

discuss proper furnace operation and maintenance.

пмти О»°¿·® Я²¼ О»°´¿½»³»²¬ Р¿®¬-

,

be sure to

provide the furnace model, manufacturing, and serial
numbers with the order.

,

all sheet metal parts, doors, etc. may be ordered by
description.

ЭСУРСТЫТМ ЧЬЫТМЧЪЧЭЯМЧСТж

1. Single Stage Gas Valve
2. Gas Manifold
3. Mini Igniter
4. Natural/Propane Gas Orifice
5. Burner
6. Door Switch
7. Integrated Contol Module
8. 24 Volt Thermostat Connections
9. Circulator Blower
10. Capacitor
11. Reverse flow switch

12. Transformer
13. Rollout Limit Switch
14. Primary Limit Switch
15. Junction Box
16. Induced Draft Blower
17. Flue Collector Box
18. Heat Exchanger
19. Blower Wheel
20. Pressure Switch
21. Pressure Switch Hose
22. Flame Sensor

Please contact your local installer or dealer for replacement parts.