Пт няъымз эстнчьыоямчстн – Klimaire GM80S Series User Manual

Page 4

Advertising
background image

î

I&O manual

î

I&O manual

пт НЯЪЫМЗ ЭСТНЧЬЫОЯМЧСТН

WARNING

Failure to follow this warning could result in dangerous opera-
tion, serious injury, death or property damage. Improper
installation adjustment alteration service maintenance
or use could cause carbon monoxide poisoning explosion
fire electrical shock or other conditions which may cause
personal injury or property damage. Consult a qualified service
agency local gas supplier, or your distributor or branch for
information or assistance. The qualified service agency must
use only factory-authorized and listed kits or accessories when
modifying this product.

FIRE, EXPLOSION, ELECTRICAL SHOCK,
AND CARBON MONOXIDE POISONING HAZARD

CAUTION

Improper installation or misapplication of furnace may require
excessive servicing or cause premature component failure.
Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, unit leveling, and unit sizing.

FURNACE RELIABILITY HAZARD

CAUTION

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care
and wear appropriate protective clothing, safety glasses and
gloves when handling parts and servicing furnaces.

CUT HAZARD

Improper installation, adjustment, alteration, service, Maintenance, or
use can cause explosion, fire, electrical shock, or other conditions
which may cause death, personal injury, or property damage. Consult
a qualified installer, service agency, or your distributor or branch for
information or assistance. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this product.
Refer to the individual instructions packaged with the kits or accesso-
ries when installing.

Follow all safety codes. Wear safety glasses, protective clothing, and
work gloves. Have a fire extinguisher available. Read these instruc-
tions thoroughly and follow all warnings or cautions include in
literature and attached to the unit. Consult local building codes the
current editions of the National Fuel Gas Code (NFGC) NFPA
54/ANSI Z223.1 and the National Electrical Code (NEC) NFPA 70.

In Canada, refer to the current editions of the National Standards of
Canada CAN/CSA-BI49.1 and .2 Natural Gas and Propane Installa-
tion Codes, and Canadian Electrical Code CSA C22.1

Recognize safety information. This is the safety-alert symbol . When
you see this symbol on the unit and in instructions or manuals, be alert
to the potential for personal injury. Understand the signal words
DANGER, WARNING, and CAUTION. These words are used with the
safety-alert symbol.

DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards which
could result in personal injury or death. CAUTION is used to identify
unsafe practices which may result in minor personal injury or product
and property damage. NOTE is used to highlight suggestions which
will result in enhanced Installation, reliability, or operation.

Use only with type of gas approved for this furnace. Refer to the
furnace rating plate.

Install this furnace only in a location and position as specified in
the "Location" section of these instructions.

Provide adequate combustion and ventilation air to the furnace
space as specified in "Air for Combustion and ventilation" section.

Combustion products must be discharged outdoors. Connect this
furnace to an approved vent system only, as specified in the
"Venting" section of these instructions.

Never test for gas leaks with an open flame. Use a commercially
available soap solution made specifically for the detection of leaks
to check all connections, as specified in the "Gas Suppy and
Piping" section.

Always install furnace to operate within the furnace's intended
temperature-rise range with a duct system which has an external
static pressure within the allowable range, as specified in the
"Start-Up, Adjustments, and Safety Check" section. See furnace
rating plate.

When a furnace is installed so that supply ducts carry air
circulated by the furnace to areas outside the space containing the
furnace, the return air shall also be handled by duct(s) sealed to
the furnace casing and terminating outside the space containing
the furnace. See "Air Ducts" section.

A gas-fired furnace for installation in a residential garage must be
installed as specified in the warning box in the "Location" section.

The furnace may be used for construction heat provided that the
furnace installation and operation complies with the first CAUTION
in the LOCATION section of these instructions.

These multipoise Gas-Fired Furnaces are CSA (formerly A.G.A.
and C.G.A). design-certified for use with natural and propane
gases (see furnace rating plate) and for installation in alcoves
attics, basements, closets, utility rooms, crawlspaces, and
garages. The furnace is factory-shipped for use with natural gas.
A CSA listed accessory gas conversion kit is required to convert
furnace for use with propane gas.

The furnaces must be kept free and clear of insulating materials.
Inspect surrounding area to ensure insulation material is in safe
distance when installing furnaces or adding insulation materials.
Insulation materials may be combustible.

See Fig. 2 for required clearances to combustible construction.

Maintain a 1 in. (25 mm) clearance from combustible materials to
supply air ductwork for a distance of 36 in. (914 mm) horizontally
from the furnace. See NFPA 90B or local code for further require-
ments.

These furnaces SHALL NOT be installed directly on carpeting,
tile, or any other combustible material other than wood flooring. In
downflow installations, factory accessory floor base MUST be
used when installed on combustible materials and wood flooring.
Special base is not required when this furnace is installed on
manufacturer's Coil Assembly .

Advertising