Relevant documents, 1 technical data, 1technical data – Richter MNK-B Series User Manual

Page 3: Series mnk-b, Close-coupled design

Advertising
background image

Series MNK-B,

close-coupled design

Page 3

9230-055-en

Revision 09

TM 7345

Edition 10/2008

Relevant documents

Data sheet
Works certificate
Sectional drawing MNK-B

9230-00-3002

Dimensional drawing

9230-00-3016

Installation drawing
Performance curves
Spare parts list
Operating manual motor
Supplementary Installation and Operating Manual
for external flushing

9230-060-en *

Supplementary Installation and Operating Manual,
vortex pump

9230-061-en *

Supplementary Installation and Operating Manual,
„self-priming“ design

9230-062-en *

*

if contained in the scope of delivery

Declaration of conformity for the entire unit to
Machine Directive 98/37/EC
Form for Safety Information Concerning the
Contamination QM 0912-16-2001_en
Pump with ATEX :
Declaration of conformity for the pump to Directive
94/9/EC

On request:

Operational limits see 9200-00-0030
Nozzle forces Richter TIS 0541-02-0006
Magnetic drive data Richter TIS 0543-03-0001
Publication: "Centrifugal Pump Operation without
NPSH Problems"
Publication "Safe Operation of Magnetic Drive
Pumps“

1

Technical data

Manufacturer :

Richter Chemie-Technik GmbH
Otto-Schott-Str. 2
D-47906 Kempen
Telephone: +49 (0) 2152 146-0
Fax:

+49 (0) 2152 146-190

E-Mail:

[email protected]

Internet:

http://www.richter-ct.com

Designation :

Single-stage, plastic-lined, magnetic drive chemical
centrifugal pump, series MNK-B, close-coupled design
from size 25-25-125
Heavy-duty horizontal design, sealless, free of eddy
currents
Technical specifications to ISO 15783 and DIN ISO
5199
Connecting dimensions to ISO 2858 / DIN EN 22858
Flange connecting dimensions:
DIN EN 1092-2, type B (ISO 7005-2, type B) PN 16
or flanges drilled to ASME 16.5, Class 150
ATEX 95 Directive 94/9/EC
Machine Directive 98/37/EC

Materials :

Pressure-bearing parts:
ductile cast iron EN-JS 1049 to DIN EN 1563 (0.7043
DIN 1693), carbon fibre composite material
Wetted parts:
PFA, PTFE, PE-UHMW, PP, PFA-P, anti-static lining
(PFA/PTFE conductive) SSiC, FKM/FFKM
see also data sheet

Flow rate : up to

100 m

3

/h

(at

2900 min

-1

)

Delivery head :

up to 90 m LC

(at

2900 min

-1

)

Housing discharge pressure :

max. 16 bar

detailed data see operational limits.

Temperature range :

- 60 °C to + 180 °C

Note: Consult the manufacturer for higher pressures

and lower or higher temperatures.

Temperature classes :

see Section 2.6.7

Admissible ambient conditions for pumps
acc. to directive 94/9/ EG (ATEX 95) :

Ambient temperature range: - 20 °C to + 40 °C
(higher temperature after consulting the manufacturer)
Ambient pressure range: 0,8 bar

abs

to 1,1 bar

abs

Sizes :

Group 1.1

Group 1.2

Group 1.3

25-25-125

25-25-160

50-32-200

50-32-125

50-32-160

65-40-200

80-50-160

80-50-200

Weight :

See data sheet

Dimensions :

See installation drawing