1 tightening torques, 2 type plate, dry-running, ce and housing markings, Tightening torques – Richter MNK-B Series User Manual

Page 4: Markings, Series mnk-b, Close-coupled design

Advertising
background image

Series MNK-B,

close-coupled design

Page 4

9230-055-en

Revision 09

TM 7345

Edition 10/2008

1.1 Tightening torques

Screws greased, tighten in diametrically opposite
sequence
Housing screws 901/3

Size

No. x size

Tightening torque

[mm]

[DIN/ISO]

[Nm]

25-25-125

8 x M 10

20

50-32-125

8 x M 10

20

25-25-160

6 x M 10

45

50-32-160

6 x M 10

45

80-50-160

6 x M 10

45

50-32-200

8 x M 12

45

65-40-200

8 x M 12

45

80-50-200

8 x M 12

45

Pipe screws, flanges to DIN/ISO

DN

No. x size

Tightening torque

[mm]

[DIN/ISO]

[Nm]

25

4 x M 12

10

32

4 x M 16

15

40

4 x M 16

20

50

4 x M 16

26

65

4 x M 16

40

80

8 x M 16

25

Pipe screws, DIN/ISO flanges drilled to ASME

DN

No. x size

Tightening torque

[mm] [inch]

[ASME]

[Nm]

[in-lbs]

25

1“

4 x ½“

8

70

32

1¼“

4 x ½“

12

105

40

1½“

4 x ½“

15

135

50

2“

4 x N“

25

220

65

2½“

4 x N“

30

265

80

3“

4 x N“

45

400

1.2 Type plate, dry-running,

CE and housing markings

The stainless steel type plate is firmly riveted to the
housing:
If the operator attaches his identification, it must be
ensured that the pump matches the application in
question.
Example of type plate:

Dry-running:

CE marking:
(only for pumps to ATEX 95)

Housing identification:

The following are visible on the housing according to
DIN EN 19:

Nominal size
Rated pressure
Housing material
Manufacturer's identification
Melt number/Foundry identification
Cast date

Advertising