PURUS CP PUMP OPERATION / MAINTENANCE MANUAL

PAGE 13

6.3 PC15 UTILITIES / HOOK-UP

Utility

Pump

Air Inlet:

 3/8” Diameter supply tube.

Air Supply:

 50-80 PSIG (.55±.03 MPa Max), clean dry air or inert

gas

Power

 24VDC - 500mA

Controller Weight:

 4.4 lbs (2.0 Kg)

ATTENTION: Air supplied to the PC15 pump controller must be regulated to 50 - 80 PSIG
to operate the vacuum venturi. An onboard precision regulator controls pump air supply
pressure.

 Air supply connections between the pump and the pump controller are required.

NOTE: 3/8” tubing required for distances not to exceed 4 meters between the pump and
the pump controller.

 24VDC is required to operate the pump controller.

o

Terminal blocks are insulation displacement type. Insert 22-16 awg wires into

the indicated location and rock lever to engage connection, see Figure 6-2.

NOTE: Follow local wiring codes and applicable wiring standards to insure proper power
and over-current protection.

Figure 6-2: 24VDC Connection