PURUS CP PUMP OPERATION / MAINTENANCE MANUAL

4 OPERATION

4.1 PRINCIPALS OF OPERATION

 The Purus CP accomplishes near pulseless flow by Cross-Phase operation (refer to

the following step-by-step illustration):

Chamber 1 – pressure / Chamber 2 – vacuum.

Chamber 1 – pressure / Chamber 2 – pressure (crossed-phase).

Chamber 1 – vacuum / Chamber 2 – pressure.

Chamber 1 – pressure / Chamber 2 – pressure (crossed-phase).

Chamber 1 – pressure / Chamber 2 – vacuum.

4.2 START

UP

 Open the fluid suction (IN) line valve, if necessary
 Open the fluid discharge (OUT) line valve, if necessary
 Set air pump supply regulator at the desired discharge pressure. Increase pressure to

attain desired outlet pressure, up to the maximum rating (See Section 3.1)

 Activate pump controller.