Start Button (over conveyor) – Used for Tunnel applications. This needs to be “off” if an

entry gate is being used in conjunction with the Portal.

Click OK to save your changes and return to the Bay Setup screen.

Wash Select II Settings

Before a Wash Select II (WSII) unit will operate with the Gate Controller, some configuration settings on
the Wash Select II must be changed. Refer to the WSII Operations Manual, Section 2.8.8: Wash
Interface Settings Tunnel
mode for more information.

You must enable the Barrier gate interface of the WSII in order for the WSII to communicate with the
gate controller.

Figure 10. Wash Select II CPU Board

1.

Using the toggle switch at the top of the CPU board, place the Wash Select II in setup
mode by moving the switch toward the back of the Wash Select II case. (The CPU board is
located on the inside right wall of the Wash Select II case.)

2.

On the WSII keypad, use the (3) key to scroll forward and the (1) key to scroll back. Scroll
through the main menu until the “Wash Interface” option is displayed. Press the (*) key to
enter.

3.

Scroll through this menu until the “Barrier Gate” option is displayed, and then press the (*)
key to enter.

4.

Press the (1) button to enable the option.


Document

Number:

GC1004

12

Document Title:

Unitec CAME Gate and Gate Controller Installation Guide