F u s e – CCI Thermal Technologies FX5 - Explosion-Proof Electric Air Unit Heater User Manual

Page 16

Advertising
background image

16

P R I N T E D C I R C U I T B O A R D

1. After removing the printed circuit board (P.C. Board) bracket assembly

from the control enclosure, separate the P.C. Board from the bracket

by cutting off the plastic spacers (see Figure 18).

2. Reinstall a new factory supplied P.C. Board onto the mounting bracket

using new non-conducting spacers of the same length. Spacers are

supplied with a new P.C. Board. Reinstall the control circuit ground

wire to the printed circuit board bracket (see Figure 9).

C O N TA C T O R

1. Loosen, but do not remove contactor mounting screws. Slide

contactor off mounting screws.

2. Replace with a factory supplied contactor of the same rating.

T R A N S F O R M E R

1. Replace with a factory supplied transformer of the same rating.

2. On the new transformer, select primary wires to match heater voltage.

Ensure that the correct transformer secondary lead is grounded (see

Figure 9). Individually terminate all unused wires using closed

end connectors.

F U S E

Replace fuse with one of the same type and rating as indicated on P.C.

Board or refer to parts list. An extra fuse should be stored in the clips

marked “SPARE”.

H E AT I N G E L E M E N T S

Heating elements are an integral part of the vacuum charged core. A factory

exchange core can be shipped immediately from stock. Refer to “Core”

section for details.

C A B I N E T PA N E L S

Bolt-on cabinet panels are individually replaceable.

FIGURE 17

FIGURE 16

1/16” to 3/16”

(1.6 to 4.8mm)

FIGURE 15

FIGURE 18