CCI Thermal Technologies FX5-SD - Explosion-Proof Electric Air Unit Heater User Manual

Page 9

Advertising
background image

9

F x 5 - s d t e c h n i c a l d ata F o r 5 0 h z

e l e c t r i c h e at e r s

C US

model

n

ote

a

ir Flow

v

oltage

n

ominal

W

attage

phase

m

ax.

m

otor

n

ameplate c

urrent

h

eater

W

attage

total

c

urrent

m

inimum circuit

a

mpacity

supply W

ire

m

aximum

Fuse

size

temperature

rise

c

ontactor

part

n

umber

(cFm) (v) (kW)

(W)

(a)

(a)

(aWg)

(a)

°c

°F

FX5-SD-220150-025

400

220

2.5

1

2.7

2270

11.4

14.3

14

15

11.0

19.8

3619

FX5-SD-220150-042

400

220

4.2

1

2.7

3950

19.1

23.9

10

25

18.4

33.2

3619

FX5-SD-220150-063

700

220

6.3

1

2.7

6050

28.6

35.8

8

40

15.8

28.5

3619

FX5-SD-220150-084

700

220

8.4

1

2.7

8140

38.2

47.8

6

50

21.1

37.9

3619

FX5-SD-220150-126 * 1450 220 12.6 1

1.4

12100 57.3

71.6

2

75

15.3

27.5

3619

FX5-SD-230150-028

400

230

2.8

1

2.7

2480

12.2

15.3

12

20

12.3

22.1

3619

FX5-SD-230150-046

400

230

4.6

1

2.7

4310

20.0

25.0

10

25

20.2

36.4

3619

FX5-SD-230150-069

700

230

6.9

1

2.7

6610

30.0

37.5

8

40

17.3

31.2

3619

FX5-SD-230150-138 * 1450 230 13.8 1

1.4

13200 59.9

74.9

2

80

16.7

30.1

3619

FX5-SD-380350-025

400

380

2.5

3

0.7

2270

3.8

4.8

16

5

11.0

19.8

3619

FX5-SD-380350-042

400

380

4.2

3

0.7

3950

6.4

8.0

16

10

18.4

33.2

3619

FX5-SD-380350-063

700

380

6.3

3

0.7

6050

9.6

12.0

14

15

15.8

28.5

3619

FX5-SD-380350-084

700

380

8.4

3

0.7

8140

12.8

16.0

12

20

21.1

37.9

3619

FX5-SD-380350-125

1450 380 12.5 3

0.7

12100 19.0

23.8

10

25

15.1

27.3

3619

FX5-SD-380350-209

3000 380 20.9 3

1.0

20300 31.8

39.8

8

40

12.2

22.0

3619

FX5-SD-400350-028

400

400

2.8

3

0.7

2480

4.0

5.0

16

5

12.3

22.1

3619

FX5-SD-400350-046

400

400

4.6

3

0.7

4310

6.6

8.3

16

10

20.2

36.4

3619

FX5-SD-400350-069

700

400

6.9

3

0.7

6610

10.0

12.5

14

15

17.3

31.2

3619

FX5-SD-400350-093

700

400

9.3

3

0.7

8900

13.4

16.8

12

20

23.3

42.0

3619

FX5-SD-400350-139

1450 400 13.9 3

0.7

13200 20.1

25.1

10

30

16.8

30.3

3619

FX5-SD-400350-185

1450 400 18.5 3

0.7

17800 26.7

33.4

8

35

22.4

40.3

3619

FX5-SD-400350-231

3000 400 23.1 3

1.0

22200 33.3

41.6

8

45

13.5

24.3

3619

FX5-SD-415350-037

400

415

3.7

3

0.7

3510

5.1

6.4

16

10

16.3

29.3

3619

FX5-SD-415350-075

700

415

7.5

3

0.7

7240

10.4

13.0

14

15

18.8

33.9

3619

FX5-SD-415350-149

1450 415 14.9 3

0.7

14500 20.7

25.9

10

30

18.1

32.5

3619

FX5-SD-415350-224

3000 415 22.4 3

1.0

21800 31.2

39.0

8

40

13.1

23.6

3619

FX5-SD-440350-042

400

440

4.2

3

0.7

3950

5.5

6.9

16

10

18.4

33.2

3619

FX5-SD-440350-084

700

440

8.4

3

0.7

8140

11.0

13.8

14

15

21.1

37.9

3619

FX5-SD-440350-168

1450 440 16.8 3

0.7

16300 27.5

34.4

8

35

20.4

36.6

3619

FX5-SD-440350-210

3000 440 21.0 3

1.0

20300 27.5

34.4

8

35

12.3

22.1

3619

notes:

* Exceeds the 48 Amp Circuit Limit of NEC 424-22. DS5 not available for these units.

1. Minimum conductor size for 30˚C (86˚F) ambient. Derate conductor for ambient temperature. Use minimum 90˚C (194˚F) insulation.

2. Heater is functioning normally if at rated voltage the amp draw is within 10% of the value in this table.

3. Operation at lower voltages will result in reduced heat output and amp draw

4. Add "T" to model number when adding a built-in thermostat

5. Add "D" to model number when adding a built-in disconnect switch

6. Add "U" to model number for units with continuous fan option.

7. Add "A" to model number for units with stainless steel cabinet.

Advertising