ClearOne MUR2EM Installation Guide User Manual

Page 11

Advertising
background image

Configuring a Single MUR2EM

NS-1005-7140

2-5

All specifications subject to change without notification. All rights reserved. Copyright © 2005 NetStreams

Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496

3600 W. Parmer Lane, Suite 100; Austin, TX 78727 /

www.netstreams.com.

Figure 2-5

Blank HyperTerminal screen

8.

Pull the power cable from your MUR2EM, wait 5 seconds, then plug it back in.

Wait 30-60 seconds while HyperTerminal connects to the MUR2EM. Shortly, the
screen displays information for the NetStreams MUR2EM and says you can make
changes if you press any key within five seconds of the information displaying.

9.

Press any key.

You are prompted to Accept or Modify the settings.

10.

Enter M to modify.

You are prompted for the root password.

11.

Enter Netsilicon (the field is case-sensitive).

You are prompted to enter your IP settings.

12.

Enter the Static IP Address and press Enter.

You are prompted to enter the Subnet mask.

13.

Enter the Subnet Mask and press Enter.

You are prompted to enter the Gateway Address.

14.

Enter the Gateway address and press Enter.

You are prompted that changes are being saved in NV memory and that the
configuration is done (see Figure 2-6).