Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

31

2013-10-29

Table of Contents

Index

196-359M

Point Row Switches

The hydraulic drive motor operates whenever the speed
radar detects motion. The Point Row system determines
whether or not that motion is coupled to the meter drives,
by controlling the electric clutches. The implement lift
switch is part of the Point Row system.

A Point Row troubleshooting chart is found on page 92.

Refer to Figure 31

Note: The Pump

switch has no function on 3N-40

drills configured by Great Plains. Unless connected
to field-installed equipment, leave it off.

When Not Planting or Calibrating

Set the Master switch

OFF when you do not intend to

meter seed.

Entanglement Hazard:
If the hydraulic drive system is on, and the drill is lowered (or
the Master switch is in CAL), unexpected motion of chains,
sprockets, shafts and seed meters can occur if the speed radar
detects motion, such as someone moving near the radar.

Normal Full Pass

1.

Set Master switch

ON (up)

Set all sections

ON (up).

Check that corresponding lamps are on.

2.

Height switch automatically energizes clutches when
row units are lowered.

Point Row in Pass

3.

Turn desired sections off as non-planting regions are
reached.

4.

Turn the sections back on before commencing next
full-width pass.

Point Row CAL Mode

When the drill is raised, the lift switch normally causes
the Point Row Monitor to disengage the clutches for each
drill section. To keep one or more clutches engaged dur-
ing hydraulic drive calibration, set the Master switch to
CAL.

For a typical 3-row calibration, set the Left section switch

on, and the center and right section switches

/

off during calibration.

Figure 31

Cab Switch Box

28246

Switch

or

Indicator

Function

MASTER

Switch

Up: ON: System enabled
Center: OFF System inactive
Down: CAL: Lift switch bypassed on

MASTER

Lamp

On: System enabled
Off: System OFF

Section

Lamps

On: Clutch enabled for that section.

Off: Clutch not energized

a

a. However, the section’s meters may still be coupled to the

drive system, if lock-up bolts are installed in the clutch.
See page 109.

LEFT

CENTER

RIGHT

Up: section enabled
Down: section disabled

PUMP

May control customer-provisioned
equipment.

Fuse

b

b. If

lamp fails to illuminate with

set ON, check the

fuse

. If open, check for damaged cable / failed clutch.

Protects switch box, clutches and
battery.

CAL Lamp

On: Lift switch overridden
Off: Lift switch active (or system off)

M

m

S

L

C

R

P

F

m

M

F

CAL

M

R

C

L

CAL

F

S

P

{

P

M

M

L C R

L

C