Gp precision population settings – Great Plains 3N-4020 Operator Manual User Manual

Page 60

Advertising
background image

56

3N-4010F/3N-4010HDF/3N-4020F

Table of Contents

Index

Great Plains Manufacturing, Inc.

196-359M

Table of Contents

Index

2013-10-29

GP Precision Population Settings

1.

Connect SiteMate computer to Console using 9-pin
serial cable

, as shown in Figure 80. Follow

instructions on page 39 to set Calibration Number.

Refer to Figure 81

2.

Press FUNCTION button until a “recipe format” win-
dow appears. Use the

/

arrow buttons to select

RAWSON mode.

Refer to Figure 82

3.

Press FUNCTION button until the Nominal Rate
appears on the display. Using the Up/Down arrow
keys, set the Nominal Rate to the same number as
you set the SiteMate. Once Nominal Rate is set,
press Function button until the main operating
screen appears, as shown in Figure 36 on page 37.

4.

Press On/VR button again to toggle to VR mode. VR
should appear on the screen along with the Rate that
is being sent from the SiteMate computer. (See Fig-
ure 37
on page 38). Verify that the rate shown on the
GP Controller Console is the same as the recipe
sent from SiteMate. Press ENGAGE button to acti-
vate the Precision Population Controller.

5.

To change rates manually when in VR mode, touch
the

/

arrow buttons. This changes the Controller to

the rate you select manually. To return to VR, touch
the ON/VR button to toggle back to VR mode.

Figure 81: SiteMate:

Rawson Recipe Mode

28320

1

Figure 82: SiteMate:

Rawson Nominal Rate

28323