2015P and 2515P

173-208M

4/11/2005

52

Refer to Figure 60

6.

Check for excess wear on meter slide (1).
Slight wear at the top corner is normal.

7.

If slide is not excessively worn, stop here. If it
is, continue with the following steps to re-
place.

Refer to Figure 61

8.

Remove retaining clip and pin from meter.

NOTE: Meter slide is spring loaded and the two
meter slide springs will be released when you pull
the pin. Use care not to lose pins and springs.

9.

Check removed pin for wear and replace if
worn.

Refer to Figure 62

10. Remove meter slide (1) with springs (2).

11. Place springs in new meter slide and install in

meter.

12. Reinstall seed meter wheel.

Figure 60

Meter slide location

18269

Retaining
clip

Figure 62

Meter slide and springs

18269

Figure 61

Meter slide retaining clip