Amico CSA Triplex SCD Modular Stack Mount User Manual

Page 17

Advertising
background image

www.amico.com

e.

Consideration shall be given to the potential effect of prevailing winds and possible sources

of airborne contamination and potential for obstruction by accumulated snow.

f.

Piping downstream of the compressor shall be routed in such a way that it is not subjected

to a temperature lower than 4˚C (40˚F).

g.

Piping and components shall be made of corrosive resistant materials such as brass, copper

or

stainless

steel.

D.

Control Panel and Alarm Sensors

The control system is C.U.L. labeled. The control system provides automatic lead/lag sequencing and automatic alter-
nation of pumps based on first-on/first-off principle with provision for simultaneous operation if required. Automatic
activation of reserve unit, if required, will activate an audible alarm as well as a visual alarm on the display screen.

1.

Control Panel Features:

Only panel components that are commercially available and not of propriety design will be considered.

a.

NEMA 12 control panel enclosure

b.

Full voltage motor starter shall be UL 508 E self-protected combination starters with

overload protection and external operators

c.

Door interlock disconnect switch

d.

90 dB alarm buzzer

e.

Visible indicator of “power on” and “compressor running” for each compressor

f.

Two control transformers with secondary circuit breaker

g.

Manual / Off Auto selector switches (Each Compressor)

h.

Transducer and RTD based control panel

i.

The RTD will digitally display the running temperature of each discharge port and shall be

field programmable to standard manufacturer’s operating parameter

j.

The calibration of the pressure transducer can be set so a non-standard transducer can be

used

2.

Touch screen controls feature a minimum 5.7”screen. Screen displays and functions include:

a.

WinCE 5.0 operating system

b.

OPC, TCP/IP and Communication drivers

c.

Ethernet connectivity with embedded web-page for remote monitoring, multi-level pass

word protected remote adjustment of all operating parameters

d.

Electronic notifications of alarms and warnings

e.

Communication expansion capability to talk over five Networks/Protocols

f.

Service alerts, runtime hour meters for each pump, system status, system pressure level all

shall

be

displayed

15

Advertising