6.4 Medical Air Systems Glossary

Definitions

ICFM

Conditions at the inlet of the compressor prior to any restrictions or

temperature changes. (i.e., inlet filters, inter-coolers, discharge manifolds

etc).

Displacement

Theoretical physical volume of the air in the compressor chamber based

upon 100% pumping efficiency, with no allowances made for heat,

friction, clearances, or other losses in the compression cycle.

Peak Calculated

The maximum estimated demand a medical facility will require of a

Load (PCL)

medical air system.

Calculated at SCFM at 100 psig.

Oil-Free Compressor •

Compressor with oil within the compressor but absent from the

compression chamber by means of seals and visible vented distance

piece, and a dry compression chamber.

Simultaneous Demand •

Operating reference to a condition where all compressors (Lead and Lag

compressors) run simultaneously to satisfy demand in excess of lead

compressor(s)

capability.

Dew Point

Temperature and pressure at which medical air will condense water

vapor into liquid water within the medical air pipeline system.

Continuous Duty •

Air compressors which can operate continuously (24 hours per day) if

Rated

necessary but normally only operate on demand.

LPM

Abbreviation for Liters per minute; a measure of the flow rate of a gas.

Quadruplex System

Medical air system with four compressors (4), each sized for 50% PCL.

ACFM

Actual Cubic Feet per Minute is an expression of actual air volume,

generally corrected for and reference to a particular pressure.

Continuous Duty

Operational reference to compressors operating 24 hours a day,

continuously.

Duplex System

Systems comprised of two (2) compressors, each rated for 100% Peak

Calculated

Load

(PCL).

Desiccant Dryer

Consists of two towers, whereby the desiccant bed in one tower dries the

air stream while a purge of dry air regenerates the desiccant bed in the

other

tower.

NTP

“Normal Temperature and Pressure”, generally accepted as 20˚C (70˚F),

14.969 psi/29.92” Hg barometric pressure, and 36% relative humidity.

Dew Point/CO Monitor •

Monitors dew point and carbon monoxide levels in medical air.

Oil-Less Compressor •

Compressor with no oil contained within the compressor.

SCFM

Standard Cubic Feet Per Minute is an expression of air at NTP.

Triplex Systems

Medical air system with three compressors (3), each sized for 100% PCL.