Amico Pipeline

Appendix C

Wiring Schematic Heater Units

The Heaters normally switch on when the temperature drops below 24°C or 75°F. If the temperature exceeds 65-75°C or
160-175°F, the Heater re-set switch will trip and the heaters will automatically switch off . To re-set the Heaters, remove
the heater covers & press the red button on the re-set switch to activate. When the Heaters are in use or switched on, it
will draw up to 3 amps of current. The Heater Cartridge is 200Watts (each side), normally both sides do not switch on
together. It depends on the fl ow of gas or climatic conditions.

Inlet Pressure

Block

Power Supply

Reset Switch

Heater Cartridge

Wires

Reset Switch

Inlet Pressure

Block

Heater Cartridge

(Inside Inlet Pressure Block)

Heater Cartridge

(Inside Inlet Pressure Block)