Wiring the Zeus Display

| 23

External Alarm

An external alarm can be connected to one or more displays on the network. The

external alarm can be a small peizo buzzer connected directly or a horn siren connected

via a relay.

Alarms are configured globally in the system i.e they can be configured on one display

and seen, heard and acknowledged from all displays. How ever the external alarm siren

can be enabled or disabled on individual displays. For information on configuring alarms

refer to the Alarms section in the Operation manual

12 - 24 V DC

1 A max

35 V DC max

Red (FUSE)

Black

Yellow

+ _

Blue

For sirens that draw more than 1 Amp use a relay

12 - 24 V DC

Red (FUSE)

Black

Yellow

+ _

Blue